We pressurize your building’s duct runs and document the CFM loss against code. NCI-certified testing for Las Vegas offices, retail, and industrial buildings.

NCI Certified
Aprilaire Partner
28 Years Experience
Get In Touch
With Us
Document The Loss
A commercial system can leak away
40%
Section-by-section CFM measurement, formatted for the binder.

On a commercial building, duct leakage is a documented number long before it is a repair. Commercial duct leakage testing exists to produce that number, the measured air loss, section by section, in CFM and as a percentage of design airflow, on paper that a code official, a commissioning agent, or an energy program will accept. We are not sealing anything during the test. We are measuring, and the deliverable is the report. What you do with it afterward is a separate decision.

The reason commercial buildings in Las Vegas need this is that their duct systems are larger, hidden above hard-lid ceilings, and run hard for six or more months a year. The average commercial system loses somewhere between 25 and 40 percent of its conditioned air before it ever reaches an occupied space, and at commercial tonnage that is a serious line item. But you cannot manage what you have not measured. Our testing isolates duct sections, pressurizes each one with calibrated equipment, and records exactly how much air it is losing, so the conversation moves from anecdote to data.

We test against the standard that applies to your project. New construction and tenant improvements in Clark County are increasingly held to a leakage threshold under the energy code, typically a single-digit percentage of system airflow, and a commissioning agent will want documentation that the installed system meets it. Existing buildings get tested to establish a baseline for an energy retrofit, a rebate application, or a capital plan. Either way, the test follows a documented NCI protocol so the numbers stand up to review.

The report names the failing sections by location, beyond a single building-wide total, so whoever acts on it, your in-house team, our crew, or another contractor, knows exactly where the air is going. If you want us to close the leaks after the test, our commercial duct sealing takes the report and seals to it. If you only need the documentation, the test stands alone and pairs cleanly with commercial air balancing as part of a full TAB scope.

Our Process
How the building gets measured
PROCESS
Documented section-by-section testing.
01

Drawing Review and Scope

We start with the mechanical drawings and the standard you are being held to, the energy-code leakage threshold for new work, or a baseline target for an existing building. That defines which sections get isolated and what number each one has to come in under.

02

Section Isolation

Commercial systems are tested in sections, not all at once. We cap and isolate individual duct runs so the leakage from one run cannot hide inside the total, which is how a building-wide pass can still conceal a badly leaking branch.

03

Pressurization and CFM Capture

Each isolated section is pressurized with calibrated test equipment to the reference pressure in the spec. We record the leakage in CFM and as a percentage of that section’s design airflow, the hard number that goes in the report.

04

Leak Mapping

Where a section fails, we locate why, using smoke at accessible joints, thermal imaging above the ceiling, and pressure mapping. The failing connections get noted by location so the repair scope writes itself.

05

Compliance Report

You receive a formal document, measured leakage per section against the applicable threshold, pass or fail per run, and the locations of the failures. It is formatted for a commissioning agent, a plan reviewer, or an energy program, and it works the same whoever does the sealing.

Why Constant
What the report has to do
DOCUMENTED
Built to survive a reviewer.

Code-Ready Documentation

Our leakage reports are formatted for building commissioning, energy-code compliance, and rebate documentation across Clark County. The number is presented the way a reviewer expects to see it.

Section-Level Honesty

We test individual runs rather than the whole building at once, so a single leaking branch cannot disappear inside an averaged pass. You find out which section is the problem, by name.

Non-Destructive Access

Most commercial testing is done through access panels and the T-bar grid with the ceiling in place. We schedule around occupancy so the building keeps operating while we measure.

Find The Leaks
The difference between assumed sealed and
TESTED

Commercial ductwork can leak a third of its conditioned air into ceiling plenums and chases before it ever reaches a person. You cannot see it and you cannot feel it, but you pay for it on every utility bill. Duct leakage testing puts an actual number on it.

We pressurize the duct system and measure the leakage rate against the building’s design and code requirement. A run we tested recently was leaking 28 percent, which is conditioned air going straight into the attic. The test tells us exactly how leaky the system is and gives us a target to seal back down to. No guessing about whether the ductwork is the problem.

For larger facilities, a leakage test before a tenant build-out or a system upgrade often pays for itself fast. See commercial duct projects in the gallery.

Commercial duct leakage testing in Las Vegas, Nevada
Proof
What facility managers
TRUST

Our energy bills made no sense for the square footage. The leakage test showed nearly a quarter of our conditioned air was disappearing into the ceiling. They gave us the number, sealed it, and the difference showed up the next billing cycle.

Facility Manager, Henderson

Questions
What Las Vegas building owners ask about
TESTING
Common questions about commercial duct leakage testing in Las Vegas.
How do you test duct leakage in a commercial building?
We isolate sections of the duct system, pressurize each one to the reference pressure in the spec with calibrated equipment, and record the airflow needed to hold that pressure. More airflow means more leakage. The result is a measured CFM figure per section.
What leakage rate has to pass?
It depends on the project. New construction and tenant improvements are typically held to a single-digit percentage of design airflow under the energy code. Existing buildings, which often exceed 25 percent, get tested to set a baseline rather than against a pass threshold.
Do you do the testing without sealing?
Yes. Testing is its own scope and its own deliverable. Many owners book the test for compliance or baseline documentation and handle the sealing as a separate decision, sometimes with a different crew. The report stands on its own.
Can you coordinate with our commissioning agent?
Yes. Our test report is formatted to drop into a commissioning package and to support the agent’s documentation rather than compete with it. We coordinate schedule and format with the agent and the general contractor.
Will testing disrupt building operations?
Minimally. Most commercial testing is done through access panels and the ceiling grid with everything in place, and we schedule the work around your occupancy so tenants and operations are not interrupted.

Still have questions? Contact us directly or call (702) 840-5163, we are happy to help.

Related Services
What pairs with a commercial test
MORE
Services that work alongside commercial duct leakage testing.
Get Started
Get the number on paper
MEASURE
Schedule commercial duct leakage testing and get a code-ready report on your building’s air loss. NCI-certified, section by section, Las Vegas.

Ready to Get Started?

Contact Constant Air Balancing & Services today for a free, no-obligation quote. We look forward to working with you.